Sanitizing Technology

TechSan V1.1

Technological and Medical Structure

  1. UV-C rays destroy viruses and bacteria by damaging their DNA or RNA, leading to mutations that prevent replication and function. This effectively inactivates the microorganisms, rendering them harmless.
    • Wavelength ranges from 200 nm-280 nm
    • Frequency ranges from 1071 THz-1500 THz
  2. Infrared (IR) radiation destroys viruses and bacteria by generating heat that disrupts cellular structures and denatures proteins. This thermal damage impairs their ability to function and replicate.
    • Wavelength ranges from 0.75 μm-1 mm
    • Frequency ranges from 0.3 THz-428.6 THz
  3. Radio frequency (RF) radiation disrupts viruses and bacteria by causing molecular vibrations that generate heat, potentially leading to cellular damage and death.
    • Frequency ranges from 30 Hz-300 GHz

“The Impact of UV-C Radiation on Viral and Bacterial DNA and RNA explores how UV-C light effectively damages the genetic material of viruses and bacteria, leading to the disruption of their replication processes.” 

TechSan V1.1 Fuctioning Mechanism (Patented)

The device utilizes both UV-C and IR technologies simultaneously to sanitize an area, effectively covering 25 m² of unoccupied space. It is designed to operate only in the absence of human presence, with a programmable timer that ensures it functions for up to 4 hours before human activity is expected and ceases operation 1.5 hours prior to human presence. The RF radiation generator is mounted on the iron structure of a building, where the radiation frequency is absorbed by the iron and then transferred to the cement. The cement, in turn, absorbs these radiations through its minerals. The primary objective is to maintain a surface that prevents the proliferation of bacteria and viruses. This system can operate continuously throughout the day, as it is safe for human exposure.

Terms of Use and Safety Instructions

  1. Human Presence: The device is designed to operate only in the absence of human presence. It features a programmable timer that ensures operation up to 4 hours before anticipated human presence and ceases functioning 1.5 hours prior to such presence.
  2. Continuous Operation: The RF radiation generator can operate continuously throughout the day as it is designed to be safe for human exposure.
  3. Operation: Follow all operational instructions provided in the user manual. Ensure the device is not in use when people are present unless explicitly designed for safe operation during such times.
  4. The manufacturer is not liable for any damage or injury resulting from misuse, or failure to follow the instructions provided.